Double
Inlet Double
Width (DIDW) low & high pressure fans and blowers
High
efficiency
(up to 84%) allowing to reach substantial savings in the electricity
consumption,
and with low noise fan levels. For a fan / blower the usual source of
noise
is the air turbulence created by the blower impeller. This series fan
has been created to obtain the lowest sound levels thank to the
aerodynamic profile
of the fan inlet cone, impeller blade shape and to the precise statical
and
dynamical balancing of the ventilator impeller.
Suitable for the air
supply
for the various applications of the ventilation, air-conditioning and
industrial
processes industry.
• Volume: from 1000 CFM
up
to 350,000 CFM
• Pressure: from 0.5"
WG up
to 15" WG
• Temperature: up to
500º
F
• Fan drive arrangement
- Direct
/ V-belt / Coupling Drives ventilators
• Construction
material: mild
steel / stainless steel / aluminum
Canada
Blower series of high efficiency airfoil bladed fan wheels is
acknowledged as the most efficient fan type for clean air applications.
Canada Blower double width fan configuration described boasts an
enviable reputation for fan performance and reliability in a multitude
of HVAC applications plus many industrial supply or exhaust ventilation
systems.
With a smooth pressure
curve, major changes in pressure will cause only minor changes in
volume. The broad, high efficiency fan curve offers extensive
selections from each fan size and also a wide operating range. The
smooth stable air flow over the entire perform-ance range is the result
of Canada Blower deep spun inlet, wheel cones and generous ventilator
housing proportions. Fan sound levels are also diminished with the
improved inlet air glide path.
Rugged blower wheels of
continuously welded heavy gauge steel provide maximum integrity and
longevity. Canada Blower wheels are also designed for high-cycle duty
common with VFD control. Impeller assembly designhas been verified with
a finite element analysis. Spun steel fan wheel cones optimize air flow
while precision balancing assures dependable vibration-free operation.
Strengthened Canada Blower ventilator housings have continuously welded
heavy steel construction with rigid steel bearing supports. Stiff
bracing resists distortion caused by sudden blower air flow variations.
For economical
performance at partial loads and precise air control for systems
needing to maintain a positive or negative pressure at minimal flow,
the Inlet Volume Control (IVC) is recommended. Adjustable guide fan
vanes pre-spin the entering air to produce the desired volume of air
while maintaining the full amount of block off pressure. Inlet vanes
are mounted entirely within the blower inlet cone. The IVC is suitable
for automatic or manual operation. Canada Blower outlet dampers are
offered for all classes of fans, outlet dampers feature low initial
cost and simple operation. However, they do not offer as large a
horsepower savings at reduced air volume as the IVC. Fan outlet dampers
have punched flanges on both ends to simplify fan and duct connections.
Damper shafts are atright angles to fans haft when possible. Parallel
acting blades are standard with opposed blade design optional. To mount
damper on the fan, a punched flanged outlet is needed.
|
|